| Item Number | OS20907 |
|---|
| Product Number | 20907 |
|---|
| Average Life (Hrs) | 20000 |
|---|
| Base Code | G5 |
|---|
| Bulb Shape | T5 |
|---|
| Case Quantity | 40 |
|---|
| Color Description | Warm White |
|---|
| Color Rendering Index | 82 |
|---|
| Color Temperature | 3000 |
|---|
| Lamp Base | Mini Bipin |
|---|
| Lamp Family | PENTRON® T5 LAMPS |
|---|
| Lamp Wattage | 14 |
|---|
| Lumen – Initial | 1200 |
|---|
| Lumen – Initial (95F) | 1350 |
|---|
| Lumen – Mean | 1116 |
|---|
| Lumen – Mean (95F) | 1256 |
|---|
| Manufacturer | Sylvania (Osram) |
|---|
| Maximum Overall Length (In) | 22.2 |
|---|
| Maximum Overall Length (mm) | 563.88 |
|---|
| Nominal Length (In) | 24 |
|---|
For linear Preheat and Rapid Start Lamps, four electrical contacts are required, two at each end of the lamp. This is accomplished in the standard line of lamps by the use of a miniature bipin base for T5 lamps and a medium bipin for T8 and T12 lamps. The OCTRON® T8 medium bipin lamps may also be operated as instant start lamps with the proper wiring and ballasts. When operating OCTRON bipin lamps with instant start ballasts, the two contacts in the lamp holder are shorted together and connected to the single circuit in the ballast. In Circline lamps, the cathodes are connected to a four-pin base located between the junction of the two ends of the lamp. High Output (HO) and Very High Output (VHO) lamps have recessed double contact (RDC) type bases. Slimline Instant Start lamps require only two electrical contacts, one on each lamp end and have single pin bases.
This ECOLOGIC® lamp was designed to pass the Federal TCLP criteria for classification as non-hazardous waste in most states. Disposal regulations may vary; check local and state regulations.
PENTRON® High Performance T5 Lamps
PENTRON® T5 lamps are designed to operate on dedicated electronic programmed rapid start (also known as programmed start) ballasts only. These lamps are globally standardized and are designed to operate with their peak light output at 35°C (95°F) ambient temperature. For comparison purposes and to accommodate existing lamp measurement standards, ratings are given at both 25°C (77°F) and 35°C (95°F). The new lamp dimensions allow for innovative fixture designs and improved fixture performance. A PENTRON Fixture Design Guide is available on request.
Initial lumens are measured when the lamp has been operating for 100 hours. Mean lumens are typically measured at 40% of the rated life of the lamp. For longer life lamp such as the OCTRON® XP™ lamps, the mean lumens are measured at the same point in time as they are measured for the standard lamps they replace. Fluorescent lamp lumens are typically measured at 25°C (77°F). The lamp lumens are measured at both 25°C (77°F) and 35°C (95°F) for PENTRON linear lamps.